AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |
Back to Blog
Instal the new Compressor1/8/2024 ![]() ![]() Fixes an issue where luminance levels could be incorrect when Job inspector colour space and Output colour space were set to Rec.Fixes an issue where Reveal in Finder was not available for clips with modified audio settings.Fixes an issue where the source/output comparison viewer would not reflect the camera log selection.Adds support for log-encoded video recorded with iPhone 15 Pro and iPhone 15 Pro Max.Good job and tell all your friends about “The Repair Matrix” a share or a nice review is all we ask. You have good pressures so we know it’s blowing cold air inside, go to end page test now. If you need more help vacuuming and charging visit page 9 now for more detailed vacuum / charge instructions.Īnd there it is folks that are how you install, change or replace a bad compressor. Keep adding charge until your superheat drops to as close to 10 degrees as you can get it without putting your sub-cooling over 20 degrees, “give me that 10, 10” I say If the system is still low on Freon the superheat will be higher than 20 degrees. If you charge wrong here the machine still may work but the compressor will fail years earlier than if you charge right. 16-18 degrees of superheat will keep this compressor running for years to come. These are the 3 main points to watch when charging and you will never get them all perfect but, you can adjust some and get the 3 as close as possible. Keep charging through the suction on for 10 seconds and off for 20 seconds until you reach as close to your 10 degrees of superheat, 20-30 degrees over ambient temperatures for the head pressure and as close to 10 degrees of sub cooling as you can get. You’ll notice the compressor is still low on charge, open your suction gauge to charge the system through the suction only.ġ1. Now that the new compressor is running were in the clear and home stretch. Or, if it pulls over 30 amps on start, you need to install a hard start kit in step 16. But, if it does not start, go back and find out where you miss-wired the compressor. The new compressor should turn on and pull less than 3o amps, if it does continue charging. Plug in disconnect and turn on air conditioner. ![]() ![]() Now put your amp probe onto the common wire for the compressor and turn it on then set it to AAC so we can watch the compressors starting amps. Close down both dials suction and high side on the gauges. Let it drink all it can and when it stops or slows to the point that it seems pointless. Hook up the recovery jug full of r-22 to the gauges as shown in diagram 8-A open the gauges and tank to allow Freon to flow to the air conditioner. Ok, now you’re stabilized below 1000 microns, let’s re-charge the system. If your microns raise some but stopped rising and stabilized below 1000 then you’re ok the rise was just moisture boiling off into a vapor so continue down the page.If you have trouble locating the leak try visiting step 21 for help.After 15 minutes has elapsed if your microns rose above 1000 you have a leak so find the leak fix it and re-vacuum.Also verify the motor spins and the blade does not hit anything like wires maybe. C-R-S your capacitor, contactor and the condenser motor. While you let the machine sit, you should go through and double check all you’re wiring. Once you reach 500 microns close the hose leading to the pump and shut off the vacuum pump. Go back to your vacuum it’s time to check where we’re at.īy now you should be at or real close to 500 microns. Once all your screws are back in the lid. P ut the air conditioners lid back onand be aware of the condenser motor wires, run them through to the electrical panel just like they were before and be sure they do not get crimped or pinched anywhere. ![]()
0 Comments
Read More
Leave a Reply. |